Bk-precision 2552-2559 - Programming Manual Instrukcja Użytkownika Strona 77

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 140
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 76
77
DESCRIPTION The PARAMETER_VALUE query returns the
measurement values.
Parameters Available on All Models
ALL
all parameters
NDUTY
negative duty cycle
AMPL
amplitude
NWID
negative width
BASE
base
OVSN
negative overshoot
CMEAN
mean for cyclic
waveform
OVSP
positive overshoot
CRMS
root mean square for
cyclic part of waveform
PKPK
peak-to-peak
DUTY
duty cycle
PER
period
FALL
falltime
RPRE
(Vmin-Vbase)/ Vamp
before the waveform
rising transition
FREQ
frequency
PWID
positive width
FPRE
(Vmin-Vbase)/ Vamp
before the waveform
falling transition
RMS
root mean square
MAX
maximum
RISE
risetime
MIN
minimum
TOP
top
MEAN
mean
WID
width
QUERY SYNTAX <trace>: PArameter_VAlue? [<parameter>, ... ,
<parameter>]
<trace>: = { C1, C2, C3, C4}
<parameter> : = See table of parameter names
on previous table.
RESPONSE FORMAT <trace>: PArameter_VAlue <parameter>,
<value> [, ... , <parameter>,<value>]
EXAMPLE The following query reads the risetime of
Channel 2
Command message:
C2: PAVA? RISE
Response message:
C2: PAVA RISE, 3.6E-9S
CURSOR
PARAMETER_VALUE?, PAVA?
Query
Przeglądanie stron 76
1 2 ... 72 73 74 75 76 77 78 79 80 81 82 ... 139 140

Komentarze do niniejszej Instrukcji

Brak uwag