DESCRIPTION The PF_CONTROL command controls the
pass/fail controlling options: operate, output
and the stop on output.
See instruments Operator Manual for these
options
The response to the PF_ CONTROL? query
indicates the controlling options of the pass/fail.
COMMAND SYNTAX PF_ CONTROL
TRACE,<trace>,CONTROL,<control>,OUTP
UT,<output>,OUTPUTSTOP,<state>
<trace> : = {C1,C2,C3,C4}
<control> : = {START,STOP}
<output> : = {FAIL,PASS}
<state> : = {ON,OFF}
QUERY SYNTAX PF_ CONTROL?
RESPONSE FORMAT PF_ CONTROL
TRACE,<trace>,CONTROL,<control>,
OUTPUT,<output>,OUTPUTSTOP,<state>
EXAMPLE The following instruction sets source to channel
1, operate to start, output to pass and
stop on output to off:
Command message:
PFCT TRACE,C1,CONTROL,START,
OUTPUT,PASS,OUTPUTSTOP,OFF
FUNCTION
PF_CONTROL, PFCT
Command /Query